{"id":127226,"date":"2022-09-07T16:53:07","date_gmt":"2022-09-07T14:53:07","guid":{"rendered":"https:\/\/me-international.de\/?post_type=docs&#038;p=127226"},"modified":"2022-09-08T14:30:27","modified_gmt":"2022-09-08T12:30:27","password":"","slug":"how-to-convert-a-biojector-iv-2-into-a-biojector-iv","status":"publish","type":"docs","link":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/","title":{"rendered":"How to convert a BioJector IV-2 into a BioJector IV"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-127599 alignright\" src=\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg\" alt=\"\" width=\"206\" height=\"300\" srcset=\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg 206w, https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001.jpg 329w\" sizes=\"(max-width: 206px) 100vw, 206px\" \/> <img decoding=\"async\" class=\"size-medium wp-image-127601 alignright\" src=\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_002-206x300.jpg\" alt=\"\" width=\"206\" height=\"300\" srcset=\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_002-206x300.jpg 206w, https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_002.jpg 329w\" sizes=\"(max-width: 206px) 100vw, 206px\" \/>Converting a BioJector IV-2 (2 syringes) into a BioJector IV (one syringe) is quite simple and does not need any tools. With our BioJector IV-2 we are able to inject two different vaccines with only one penetration BUT with two separate syringes.The two vaccines are coming together only for the injection (in the needle).<\/p>\n<h2>Step by Step instruction:<\/h2>\n<ol>\n<li>Make sure that the BioJector IV-2 is &#8220;Off&#8221; and there is no vaccine bottle\/bag connected to the syringes.<\/li>\n<li>Take out the two syringes from the BioJector.<\/li>\n<li>Demount part no. 530500; Syringe Tip with fitting (marked red at the left syringe; picture below) and replace it with art. no. 530006 Syringe Tip.<br \/>\n<strong>Attention!<\/strong> Make sure that all valves and springs are still inside.<\/li>\n<li>Put away the right syringe incl. tube and the tip nut with fitting.<\/li>\n<li>Put back the left syringe into the BioJector (Left Syringe-holder).<\/li>\n<li>Before you start to vaccine with the BioJector please make sure that all settings are correct. Therefore please read our BioJector manual.<\/li>\n<\/ol>\n<p>Do <strong>NOT<\/strong> vaccinate before checking all settings carefully.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Converting a BioJector IV-2 (2 syringes) into a BioJector IV (one syringe) is quite simple and does not need any tools. With our BioJector IV-2 we are able to inject two different vaccines with only one penetration BUT with two separate syringes.The two vaccines are coming together only for the injection (in the needle). Step [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[169],"doc_tag":[],"class_list":["post-127226","docs","type-docs","status-publish","hentry","doc_category-biojector-iv-iv-2-x-en"],"year_month":"2026-05","word_count":172,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"author_nicename":"dm1n","author_url":"https:\/\/me-international.de\/en\/author\/dm1n\/"},"doc_category_info":[{"term_name":"BioJector IV \/ IV-2 \/ X","term_url":"https:\/\/me-international.de\/en\/support-category\/biojector-iv-iv-2-x-en\/"}],"doc_tag_info":[],"author_list":[{"ID":"1","user_login":"@dm1n","display_name":"@dm1n","id":"1"},{"ID":"2","user_login":"amguth","display_name":"amguth","id":"2"},{"ID":"4","user_login":"CGWRedaktion","display_name":"CGWRedaktion","id":"4"},{"ID":"3","user_login":"NiMueller","display_name":"NiMueller","id":"3"},{"ID":"7","user_login":"peter.bahrenberg","display_name":"Peter Bahrenberg","id":"7"},{"ID":"6","user_login":"SNitsch","display_name":"Sarah Nitsch","id":"6"},{"ID":"5","user_login":"W@rtunG","display_name":"W@rtunG","id":"5"}],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to convert a BioJector IV-2 into a BioJector IV - ME International<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to convert a BioJector IV-2 into a BioJector IV - ME International\" \/>\n<meta property=\"og:description\" content=\"Converting a BioJector IV-2 (2 syringes) into a BioJector IV (one syringe) is quite simple and does not need any tools. With our BioJector IV-2 we are able to inject two different vaccines with only one penetration BUT with two separate syringes.The two vaccines are coming together only for the injection (in the needle). Step [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/\" \/>\n<meta property=\"og:site_name\" content=\"ME International\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-08T12:30:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/\",\"url\":\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/\",\"name\":\"How to convert a BioJector IV-2 into a BioJector IV - ME International\",\"isPartOf\":{\"@id\":\"https:\/\/me-international.de\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg\",\"datePublished\":\"2022-09-07T14:53:07+00:00\",\"dateModified\":\"2022-09-08T12:30:27+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/#primaryimage\",\"url\":\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg\",\"contentUrl\":\"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/me-international.de\/en\/#website\",\"url\":\"https:\/\/me-international.de\/en\/\",\"name\":\"ME International\",\"description\":\"Mit unseren Produkten erleichtern wir die t\u00e4gliche Arbeit unseren Kunden auf der ganzen Welt und tragen zum Tierwohl bei.\",\"publisher\":{\"@id\":\"https:\/\/me-international.de\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/me-international.de\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/me-international.de\/en\/#organization\",\"name\":\"ME International\",\"url\":\"https:\/\/me-international.de\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/me-international.de\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/me-international.de\/wp-content\/uploads\/cropped-logo_me-international-1.png\",\"contentUrl\":\"https:\/\/me-international.de\/wp-content\/uploads\/cropped-logo_me-international-1.png\",\"width\":500,\"height\":281,\"caption\":\"ME International\"},\"image\":{\"@id\":\"https:\/\/me-international.de\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to convert a BioJector IV-2 into a BioJector IV - ME International","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/","og_locale":"en_US","og_type":"article","og_title":"How to convert a BioJector IV-2 into a BioJector IV - ME International","og_description":"Converting a BioJector IV-2 (2 syringes) into a BioJector IV (one syringe) is quite simple and does not need any tools. With our BioJector IV-2 we are able to inject two different vaccines with only one penetration BUT with two separate syringes.The two vaccines are coming together only for the injection (in the needle). Step [&hellip;]","og_url":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/","og_site_name":"ME International","article_modified_time":"2022-09-08T12:30:27+00:00","og_image":[{"url":"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/","url":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/","name":"How to convert a BioJector IV-2 into a BioJector IV - ME International","isPartOf":{"@id":"https:\/\/me-international.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/#primaryimage"},"image":{"@id":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/#primaryimage"},"thumbnailUrl":"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg","datePublished":"2022-09-07T14:53:07+00:00","dateModified":"2022-09-08T12:30:27+00:00","inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/me-international.de\/en\/support\/biojector-iv-iv-2-x-en\/how-to-convert-a-biojector-iv-2-into-a-biojector-iv\/#primaryimage","url":"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg","contentUrl":"https:\/\/me-international.de\/wp-content\/uploads\/BioJector_013_001-206x300.jpg"},{"@type":"WebSite","@id":"https:\/\/me-international.de\/en\/#website","url":"https:\/\/me-international.de\/en\/","name":"ME International","description":"Mit unseren Produkten erleichtern wir die t\u00e4gliche Arbeit unseren Kunden auf der ganzen Welt und tragen zum Tierwohl bei.","publisher":{"@id":"https:\/\/me-international.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/me-international.de\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/me-international.de\/en\/#organization","name":"ME International","url":"https:\/\/me-international.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/me-international.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/me-international.de\/wp-content\/uploads\/cropped-logo_me-international-1.png","contentUrl":"https:\/\/me-international.de\/wp-content\/uploads\/cropped-logo_me-international-1.png","width":500,"height":281,"caption":"ME International"},"image":{"@id":"https:\/\/me-international.de\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/docs\/127226"}],"collection":[{"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/comments?post=127226"}],"version-history":[{"count":0,"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/docs\/127226\/revisions"}],"wp:attachment":[{"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/media?parent=127226"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/doc_category?post=127226"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/me-international.de\/en\/wp-json\/wp\/v2\/doc_tag?post=127226"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}